603 4th Ave N
Clanton, AL 35045
205-755-3369

Our Top Cities


Local Reviews

Rated 5.0 out of 5 stars based on 62 customer reviews

Always great service and friendly

I had to get a new unit. Very helpful in that process. Installing crew- Brian and Brian was great and friendly. Jacob price had to do a service call to install a part a week later. Jacob has been here 3 times within a years time and he is always nice and does great work and very knowledgeable/know his job and works very efficient. Don’t mind being ask questions. Also the office people are very nice. I would and will recommend Giles cooling and heating.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Gayle

Fast, efficient, courteous. Thank you, Jacob.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service at a Great Price

Nick at Giles Cooling and Heating did an amazing job servicing my unit. He was prompt and courteous for the appointment, explained my options of repair or replacement well. He contacted me when my part arrived and scheduled an install time that was convenient for me. I will definitely use Giles for all of my heating and cooling needs! Excellent service at a great price!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

Very polite and explained everything to us.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Owner

Tech was very professional and polite.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Barbara

Great service. Really nice technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

nome

  • Overall Experience
  • Quality
  • Price
  • Convenience

Diane

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely and great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Evan W.

Evan W. Job Checkin

Found flare on the txv leaking. Re-made the flare, leak checked and got the customers unit back cooling properly.


Evan W.

Evan W. Job Checkin

Found and replaced a bad capacitor that was keeping the condenser fan from running.


Jacob P.

Jacob P. Job Checkin

Found that both outdoor units were not coming on. So I tested the capacitors and both were bad. Replaced both of and the house is cooling down properly.


Jacob P.

Jacob P. Job Checkin

Customer said the unit was not blowing any air out the vents. I tested the blower control board and it was bad. So I replaced it and everything is cooling properly!

Customer said the unit was not blowing any air out the vents. I tested the blower control board and it was bad. So I replaced it and everything is cooling properly!

Jacob P.

Jacob P. Job Checkin

Found the indoor unit was freezing up it was low of refrigerant and has a leaking evaporator coil customer decided to go with a new A/C system.

Found the indoor unit was freezing up it was low of refrigerant and has a leaking evaporator coil customer decided to go with a new A/C system.

Jacob P.

Jacob P. Job Checkin

When I went out yesterday the customer said the unit was not cooling tested and found that the breaker was bad replaced it and everything is cooling fine!


Evan W.

Evan W. Job Checkin

Found and replaced a bad transformer.


Jacob P.

Jacob P. Job Checkin

Installed the new unit for the customer and it is cooling great!

Installed the new unit for the customer and it is cooling great!

Jacob P.

Jacob P. Job Checkin

Customer stated that the unit was not cooling. I found that the drain was stopped up and it fill the emergency pan full of water causing the float switch to trip. I removed all the water everything is cooling great!

Customer stated that the unit was not cooling. I found that the drain was stopped up and it fill the emergency pan full of water causing the float switch to trip. I removed all the water everything is cooling great!

Evan W.

Evan W. Job Checkin

Customers unit was not cooling properly, I adjusted the refrigerant charge and checked all other operation.

Customers unit was not cooling properly, I  adjusted the refrigerant charge and checked all other operation.

Nick  C.

Nick C. Job Checkin

Replacing old compressor.

Replacing old compressor.

Joshua J.

Joshua J. Job Checkin

Cleaned outdoor coils and checked ref. Blowed out drain line and checking indoor coils.. check filter and thermostat.. all is ready for the summer..

Cleaned outdoor coils and checked ref. Blowed out drain line and checking indoor coils.. check filter and thermostat.. all is ready for the summer..

Evan W.

Evan W. Job Checkin

Found an emergency drain Pan full and the float switch engaged. Removed water from the pan, cleared the primary drain, and checked all unit operation.


Evan W.

Evan W. Job Checkin

Completed final inspection on a newly installed system to make sure everything was completed properly and to answer any questions the customer had.


Jacob P.

Jacob P. Job Checkin

Customer stated that the unit was not cooling. I found the condenser motor had gone out, So I replaced it under warranty and got them back cooling again.We work on all kinds of units!

Customer stated that the unit was not cooling. I found the condenser motor had gone out, So I replaced it under warranty and got them back cooling again.We work on all kinds of units!